Chimney Extension
Installation (optional)
Optional chimney extensions and telescoping extensions
are used to fill the space between the hood and ceiling
(available for separate purchase). Chimney extensions fill
the space between the hood and ceiling of 8' (2.4 m) and 9'
(2.7 m) ceilings. Telescoping extensions accommodate 10'
(3 m) ceilings. For dealer information, visit the Find a
Dealer section on our website at www.thermador.com.
Chimney Extension Installation
IMPORTANT NOTE: Secure the Chimney Hood to the wall
before installing the Chimney Extension. See “Hanging the
Chimney Hood” on page 11 before securing the actual
Extension.
1. Installation of the chimney hood should maintain a
minimum height of 30" (762 mm) from the bottom of the
hood to the cooking surface. To determine placement
of the hood with a Chimney Extension, the height of the
chimney extension must be calculated (see
“Calculating Optional Duct Cover Height” on page 9).
2. From inside of hood, screw the supplied 5/8” (16 mm)
sheet metal screws through the holes on each side and
along the front into bottom of the extension, as shown
in Figure 21. (Screw quantity is dependent on hood
size.)
Telescoping Chimney Extension
Installation
IMPORTANT NOTE:
Secure the Chimney Hood to the wall after installing the
Extension Mounting Bracket, but before installing the
Telescoping Chimney Extension. See “Hanging the
Chimney Hood” on page 11 before securing the actual
Extension.
Securing the Telescoping Chimney Extension Bracket
1. Ensure that the minimum height of 30" (762 mm) from
the bottom of the hood to the cooking surface will be
maintained (see “Calculating Optional Duct Cover
Height” on page 9).
2. Locate two studs at the mounting location, as shown in
Figure 22.
3. At the wall stud locations, measure ǫ” (16 mm) down
from the ceiling to the top of the bracket.
MODEL 6” EXTENSION 12” EXTENSION
HPCN36NS CHMHP366N CHMHP3612N
HPCB36NS CHMHP366N CHMHP3612N
HPCN48NS CHMHP486N CHMHP4812N
HPCB48NS CHMHP486N CHMHP4812N
Figure 21: Attachment of Chimney Extension to Hood
1
2
measurements in inches (mm)
Figure 22: Hood Location
18” (457)
18” (457)
18” (457)
B
B
B
A
A
18” – 35”
( 457 – 889)
18” – 35”
( 457 – 889)
18” – 35”
( 457 – 889)
⅝” (16)
⅝” (16)
18”
(457)
18”
(457)
18”
(457)
17”
(432)
17”
(432)
17”
(432)
AB
36" 14" (356) 20¾" (527)
48" 14" (356) 32⅞" (835)