Thermador HPCN36NS Installation Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 63
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
English 13
Blower Motor Installation
HPCB36NS and HPCB48NS models have a VTN1080
integral blower included. All other blower models are sold
separately. Use only THERMADOR blowers with these
ventilation hoods. See Table 1 Blower & Circuit Breaker
Ratings for recommended blowers. Contact Customer
Service for additional options.
All hood models are rated for 120V AC installed with a
blower listed in Table 1, using a 15 amp dedicated circuit
breaker.
Blower selection will vary based on the volume of air that
needs moved and the length and location of the duct run.
For long duct runs with multiple turns and bends, consider
using a more powerful blower. For the most efficient air-
Àow exhaust, use a straight run or as few elbows as
possible (refer to “Ductwork Preparation” on page 6).
Integral Blower Installation Only
1. The blower is attached to the hood using weld studs
provided on the mounting plate (see Figure 14).
2. Guide the motor mounting plate over the studs.
3. Attach (4) nuts (included with hood) to the weld studs.
Tighten nuts with a 3/8” (9 mm) nut driver to secure the
blower to the hood.
Wiring the Hood with an Integral Blower
Integral Blower model VTN1080 should be installed after
hood is mounted to the wall.
Blower SKU
Voltage
(AC)
Blower
Current
(Amps)
**Circuit
Breaker
(Amps)
Remote VTR630* 120 4.2 15
Remote VTR1030* 120 5.7 15
Remote VTR1330* 120 8.5 15
Inline VTI610* 120 4.2 15
Inline VTI1010* 120 5.7 15
Integral VTN1080* 120 5.4 15
* Indicates a letter designating the release year.
** With blower installed.
Table 1: Blower & Circuit Breaker Ratings
CAUTION!
To reduce the risk of fire and electric shock, install this
range hood only with the blowers listed in Table 1.
WARNING!
Cutting the plug of the blower will void the warranty or
eligibility for return or exchange.
Figure 14: Integral Blower Motor Install
measurements in inches (mm)
Figure 15: Integral Blower Model VTN1080
Blower Housing
Hood Top
Plate
Transition
Hood Back
Plate
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 62 63

Comments to this Manuals