Electrical Requirements
The unit requires a 120V AC, 60Hz. 15A branch circuit.
The hood should only be connected to a dedicated circuit
(with ground) that has been installed according to relevant
regulations.
When connected to a GFCI-protected supply,
THERMADOR PROFESSIONAL hoods are suitable for
use in damp locations that are protected from outside
weather conditions and not subject to saturation with water
and other liquids, but can be subject to moderate degrees
of moisture (such as an outdoor covered patio or lanai
area). Refer to local codes, NEC/CEC, and or the Authority
Having Jurisdiction (AHJ) for additional information.
Check your local building codes for proper method of
installation. In the U.S., if there are no applicable local
codes, this unit should be installed in accordance with the
National Electric Code ANSI/NFPA No. 70, Current Issue.
In Canada, installation must be in accordance with the CAN
1- B149.1 and .2 - Installation Codes for Gas Burning
Appliances and/or local codes.
The appliance must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing a wire that allows the electric current to
escape.
Electrical Data on the Data Rating Plate:
Data, including the model and serial number, is located on
the product data rating plate inside the appliance, visible
after removal of the filter frame (see Figure 29 on page 19).
Hood Transition
Assembly of the Transition:
The overall height of the transition is 8Ǫ" (212 mm). The
hood transition sits 6½” (165 mm) above the top of the
hood. 1Ǭ" will mount below the top edge of the hood. See
Figure 4 on page 9 for overall hood dimensions.
1. Align mounting holes at base of transition with the
mounting holes of the ½” (13 mm) flange located at the
top.
2. Fasten transition to hood using (4) 1” (25.4 mm) sheet
metal screws, included with hood.
3. Seal connection between transition and hood with
aluminum tape.
4. Remove tape holding damper closed.
CAUTION!
This range hood must be properly grounded. The unit
should be installed by a qualified electrician in
accordance with all applicable national and local
electrical codes.
WARNING!
The appliance must be grounded.