Thermador PRG366JG Installation Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
English 13
Important Installation Information:
The anti-tip bracket may be attached to a solid wood
cabinet having a minimum wall thickness of 3/4”
(19mm).
The thickness of the wall or floor may require use of
longer screws, available at your local hardware store.
Use appropriate anchors when fastening the mounting
bracket to any material other than hard-wood or metal.
In all cases, at least (2) of the bracket mounting screws
must firmly fasten the anti-tip bracket to the floor, and
(2) of the mounting screws (or drywall anchors) must
firmly fasten the anti-tip bracket to the rear wall (see
Figure 8 and Figure 9).
Mounting the Anti-Tip Bracket
1. Prepare holes at fastener locations as identified below:
For walls, wall studs, or floors composed of solid
wood or metal, drill 1/8” (3.17mm) pilot holes.
For walls or floors composed of drywall, sheet-
rock or other soft materials, drill 3/16” (4.76mm)
holes to a minimum depth of 1
3
/
4
” (44mm), then tap
plastic anchors into each of the holes using a
hammer.
For walls or floors composed of concrete or
concrete block, drill 3/16” (4.76mm) holes to a
minimum depth of 1
3
/
4
” (44mm), then tap concrete
anchors into each of the holes using a hammer.
For walls or floors having ceramic tile covering,
drill 3/16” (4.76mm) holes through the tile only, then
drill into the material behind the tile as indicated
immediately above.
Place bracket on floor near the center of where the unit
is to be finally located (shown in Figure 8).
If the range is moved to a new location, the Anti-Tip
Device must be reinstalled.
2. Secure bracket into the wall stud and to the floor using
the screws provided.
3. Later, when the unit is installed, the adjustable legs will
allow the cast base to slide under the bracket hook,
stabilizing the unit.
FIGURE 8: ANTI-TIP BRACKET MOUNTING LOCATION
3”
(76mm)
FIGURE 9: ANTI-TIP BRACKET
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 95 96

Comments to this Manuals

No comments