HEAT LAMP REPLACEMENT
(for PH Wall Hood Models Only)
Turn heat lamp counterclockwise to remove.
Replace lamp with either a PAR-38 175W heat
lamp or a PAR-40 250W heat lamp.
The PAR-38 175W heat lamp provides a tighter seal
within the enclosure and produces the same amount
of effective heat with lower energy consumption.
These lamps may not be readily available at local
retail outlets. The PAR-40 250W heat lamp is readily
available at local retail outlets.
To order PAR-38 175 heat lamps with a credit card,
phone:
• OpTechInc. 800-848-6624 or
• www.bulbs.com 888-455-2800
CAUTION
DO NOT TOUCH THE BULBS IMMEDIATELY
AFTER USE.
THE BULBS WILL REMAIN HOT
FOR SEVERAL MINUTES. DO NOT PLACE
HIGHLY FLAMMABLE MATERIAL ON WARMING
SHELVES.
MAINTENANCE
LIGHTS
NOTE: Turn off the lights and fan. Allow the lights
to cool before handling. If new lights do not operate,
be sure lights are inserted correctly before calling
service.
Halogen Light Replacement
(for PH and PHI Model Wall and
Island Hoods)
Using a flat edge from a screwdriver or equivalent
tool, pry loose the lens cover as shown in Figure
5.
Remove the damaged light and replace with a
new 12 Volt, 20 Watt (maximum) halogen light
made for a G-4 base. Follow package directions
and do not touch new light with bare hands.
Reinstall the light and cover.
Figure 5