Step 6: Electrical Requirements, Connection & Grounding
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
ON accidentally.
For these gas range models, a neutral supply wire must be
provided from the power source (breaker) because critical
range components, including the surface burner spark
reignition modules, require 120 VAC to operate safely and
properly.
If the correct power supply circuit is not provided, it is the
responsibility and obligation of the installer and user to
have proper power supply connected. This must be
accomplished in accordance with all applicable local codes
and ordinances by a qualified electrician. In the absence of
local codes and ordinances, the power supply connection
shall be in accordance with the National Electrical Code.
Observe all governing codes and ordinances when
grounding. In the absence of these codes or ordinances
observe National Electrical Code ANSI/NFPA No. 70
current issue. Electric wiring diagrams and schematics
have been placed in the kick panel area of the range for
access by a qualified service technician (refer to Figure 23
on page 22).
Before you plug in an electrical cord, be sure all controls
are in the OFF position.
Do not cut or remove the ground prong. It must be plugged
into a matching grounding type receptacle to avoid
electrical shock. If there is any doubt as to whether the wall
receptacle is properly grounded, the customer should have
it checked by a qualified electrician.
INSTALLER — show the owner the location of the circuit
breaker. Mark it for easy reference.
IMPORTANT:
Dedicated 20 AMP service is required for ranges with an
electric griddle or grill.
MODEL
TYPE
VOLTAGE
CIRCUIT
RATING
FREQUENCY PHASE
30" 120 VAC 10 Amps 60 Hz. Single
36" 120 VAC 10 Amps 60 Hz. Single
36” with griddle 120 VAC 20 Amps 60 Hz. Single
36” with grill 120 VAC 20 Amps 60 Hz. Single
48” with griddle 120 VAC 20 Amps 60 Hz. Single
48” with grill 120 VAC 20 Amps 60 Hz. Single
Table 2: Electrical Supply Circuit Requirements
WARNING!
An improper 120 VAC power supply will cause
malfunction, damage to this appliance, and possibly
create a condition of shock hazard.