Thermador PRG364NLH Installation Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 85
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
English 9
NOTE:
The range is designed for flush installation to the back wall.
For a successful installation, it may be necessary to
reposition the gas supply line and electrical cord as the
range is pushed back to its final position.
-- SUGGESTION:
This may be accomplished by carefully pulling on a
rope or twine looped around the gas or electrical
supply line as the range is pushed back into its final
installed position.
IMPORTANT:
The cord supplied with the gas ranges having an electric
griddle requires a NEMA 5-20 receptacle. All other gas
units require a NEMA 5-15 receptacle, as shown below.
Electrical Supply
Installation of the range must be planned so that the rough-
in of the terminal block for the receptacle will allow
maximum clearance to the rear of the unit. To minimize
binding when the unit is connected to the receptacle or
terminal block, orient the receptacle and slide back into
position.
When the power supply cord is connected to the mating
receptacle, the combined plug/receptacle connection
should protrude no more than 2” (51 mm) from the rear
wall, see Figure 3b.
Step 3: Unpacking and Moving
the Range
Unpacking the Range
1. Remove the outer carton and packing materials from
the shipping pallet but leave the adhesive-backed foam
layer over brushed-metal surfaces, to protect finish
from scratches, until the range is installed in its final
position.
2. It is recommended that the grates, griddle plate, burner
caps and oven racks be removed to facilitate handling.
If desired, the oven doors may also be removed (see
“Step 8: Door Removal and Adjustment” on page 21).
Do not remove the griddle assembly.
WARNING!
This appliance is equipped with a three-prong grounding
plug for protection against shock hazard and should be
plugged directly into a properly grounded receptacle. DO
NOT cut or remove the grounding prong from this plug.
DO NOT ALTER THIS PLUG.
3/8*
1(0$
5(&(37$&/(
1(0$
5(&(37$&/(
Figure 5: Wall Connection
30"
RANGE
36"
RANGE
48"
RANGE
Shipping Weight 372 lbs
(169 kg)
419 lbs
(190 kg)
565 lbs
(256 kg)
Weight without
packing materials
290 lbs
(132 kg)
310 lbs
(141 kg)
421 lbs
(191 kg)
Table 1: Range Weight
7KLVSURGXFWPXVWEHSURSHUO\JURXQGHG
/05&1MVHTUZMFTNBZWBSZ
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 84 85

Comments to this Manuals