There are three sizes of Thermador Pro Harmony Ranges to choose
from30-inch, 36-inch and 48-inch. All models are available in your
choice of all-gas or dual-fuel congurations. Pro Harmony Ranges
feature a compact, 24-inch deep design in stainless steel with
porcelain cooktop surface. Dual-fuel models are LP convertible by
ordering the specied kit.. All-gas models are available in Natural
Gas or Liquid Propane and should be ordered separately from the
factory. Be sure to reference the correct model information in this
design guide.
INSTALLATION CONSIDERATIONS
The information in this design guide provides key features, product
dimensions, cutouts and installation specications. Before installing
a Thermador Pro Harmony Range, be sure to verify the cutout
dimensions and electrical / gas connections. Also, always consult with
the installation manual packed with the product for complete details
before installing.
INSTALLATION OPTIONS
Thermador Pro Harmony
®
Ranges feature a bold, professional design
and a compact, 24-inch depth prole that creates a seamless look
within standard cabinetry. These ranges can be installed in a wall or
island installation.
BACKGUARDS
When using the Flush Island Trim, Thermador recommends a
minimum 12" (305 mm) rear clearance to a combustible surface (see
Figure 1, Cabinet Clearances). Clearances from non-combustible
materials are not part of the ANSI Z21.1 scope and are not certied
by CSA. Clearances of less than 12" (305 mm) must be approved by
the local codes and / or by the local authority having jurisdiction.
NATURAL GAS OR LP
Thermador Dual-Fuel Pro Harmony Ranges are shipped by the factory
to operate on natural gas. They must be converted for use with
propane. Verify that the type of gas being used at the installation site
matches the type of gas used by the appliance. If the location / job
site requires conversion from natural gas to propane (LP), order an
LP conversion kit. Field conversion must be done by qualied service
personnel only. Please refer to the LP Conversion Instructions packed
with product for further information.
VENTILATION REQUIREMENTS
We strongly recommend that a Thermador Professional
®
Wall or
Island Hood or Custom Insert be installed with all Thermador Pro
Harmony Ranges. Downdraft ventilation should not be used. Do not
install a microwave-hood combination above the cooktop, as these
types of units do not provide the proper ventilation and are not
suitable for use with Thermador Pro Harmony Ranges.
For high output gas cooktops (60,000 BTU or greater), the minimum
of one (1) CFM of ventilation per 100 BTU is recommended. If the
cooktop has a grill or griddle, add 150 CFM to the estimated blower
capacity. Additional blower capacity may be required for longer
duct runs.
IMPORTANT VENTILATION NOTES:
Due to the high surface temperature output of the Pro Harmony
Ranges (excluding 5-burner models), the HPWB Professional
Series Wall Hoods or the Professional Series Custom Inserts are
recommended ventilation solution for these ranges. The PH
Professional Series Wall Hoods are also a viable option.
For wall installations, the hood width must, at a minimum, equal the
nominal width of the appliance cooking surface. Where space
permits, a hood larger in width than the cooking surface may be
desirable for improved ventilation performance.
For island installations, the hood width should, at a minimum,
overhang the appliance cooking surface by 3" on each side.
Due to the high heat capability of these cooktops, particular
attention should be paid to the hood and duct work installation to
assure it meets local building codes.
For best smoke elimination, the lower edge of the hood should be
installed 30"–36" above the appliance cooking surface.
If the hood contains any combustible materials (i.e., a wood
covering), it must be 36"or greater distance above the cooking
surface.
WIDTH CONFIGURATION
VENTILATION
OPTIONS
30" 4 Burners 30" or 36" Pro Wall Hood
42" Island Hood
36" Custom Insert
30" 5 Burners 30" or 36" Pro Wall Hood
42" Island Hood
36" Custom Insert
36" 4 Burners
w/Grill OR Griddle
36" or 42" Pro Wall Hood
36" Chimney Wall Hood
42" Island Hood
36" Custom Insert
36" 6 Burners 36" or 42" Pro Wall Hood
36" Chimney Wall Hood
42" Island Hood
36" Custom Insert
48" 4 Burners
w/Grill AND Griddle
48" or 54" Pro Wall Hood
48" Chimney Wall Hood
42" Island Hood
48" or 54" Custom Insert
48" 6 Burners
w/Grill OR Griddle
48" or 54" Pro Wall Hood
48" Chimney Wall Hood
42" Island Hood
48" or 54" Custom Insert
VENTILATION REQUIREMENTS (CONTINUED)
The following table indicates the ventilation hood options that are
recommended for use with Thermador Pro Harmony Ranges. Refer
to the Ventilation section or www.Thermador.com for a complete
selection of Professional ventilation options, blowers, and accessories.