ELECTRICAL SPECIFICATIONS
The appliance comes with a 3-wire power supply cord, UL-listed in
the USA and requires a 3-wire receptacle that is tted with a 15- or
20-Amp fuse.
The cord length is 50" (1270 mm).
GROUNDING INSTRUCTION
This appliance must be grounded. In the event of a malfunction
or breakdown, grounding will reduce the risk of electric shock by
providing a path of least resistance for the electric current.
ADDITIONAL GROUNDING PROCEDURE
Some local regulations may require a separate ground. In such
cases, the required accessory ground wire, clamp and screw must
be purchased separately. Never ground the appliance to plastic
plumbing lines, gas lines or water pipes.
A 4-conductor cord shall be used when the appliance is installed in an
area where local codes do not permit grounding through the neutral.
Power supply cord must be replaced by a licensed electrician only.
WARNING
Improper connection of the equipment grounding conductor may
result in electric shock. Have the appliance checked by a qualied
electrician or service technician if you are in doubt as to whether the
appliance has been properly grounded.
ELECTRICAL LOCATION
For standard 24" (610 mm) depth cutouts, the receptacle should be
recessed in the rear wall or located to either side of the cutout. For
deeper25" (635 mm) or greatercutouts, the receptacle may be
located on the rear wall, however, the recommended location for any
depth cutout is to the right or left side of the cutout. If receptacle is
placed outside of the cutout, a 2
1
/
2
" (63 mm) diameter access hole is
recommended to accommodate the 3-wire power supply cord.
MODEL OPTIONS
The under-counter refrigeration series includes a glass door wine
reserve (available with a right or left door swing) and a double
refrigerator drawer unit. All units install fully ush to be seamlessly
integrated into 24" depth cabinetry. Each unit is available custom-
panel ready or in stainless steel with a Masterpiece
®
or Professional
Handle to complement the entire collection of Thermador appliances.
INSTALLATION CONSIDERATIONS
LOCATION
The appliance should be installed in a dry, ventilated room. It may not
be installed outdoors. The ambient temperature of the room should
stay between 55°F (13°C) and 110°F (43°C).
The appliance should not be exposed to excessive heat. If installation
next to a heat source, such as an oven, radiator, etc. is unavoidable,
use a suitable insulating plate or observe the following minimum
distances from the heat source:
– 1
1
/
4
" (30 mm) from an electric cooking appliance,
11
13
/
16
" (300 mm) from an oil or solid-fuel cooking appliance.
Ensure that the exterior air vent is not blocked by cabinetry or other
elements.
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15

Comments to this Manuals

No comments